Amplified output – General purpose
AC6
Salida amplificada - De uso general
AC6
Salida amplificada - De uso general
Características principales
- Temperature limits: -40 ... +350°C for type T -40 ... +750°C for type J -40 ... +900°C for type E -40 ... +1000°C for type K (see table for sheath diameters)
- Tolerance (IEC standard 584.2/Class 2): for T: ± 1°C (-40 ... +133°C) ± 0.0075 [t] (t > +133°C) for J, E, K: ± 2,5°C (-40 ... +333°C) ± 0.0075 [t] (t > +333°C)
- Ceramic insulation of the thermocouple element
Datos técnicos
Panorámica
- Temperature limits:
-40 … +350°C for type T
-40 … +750°C for type J
-40 … +900°C for type E
-40 … +1000°C for type K
(see table for sheath diameters) - Tolerance (IEC standard 584.2/Class 2):
for T:
± 1°C (-40 … +133°C)
± 0.0075 [t] (t > +133°C)
for J, E, K:
± 2,5°C (-40 … +333°C)
± 0.0075 [t] (t > +333°C) - Ceramic insulation of the thermocouple element
- Application versatility
Otros productos